GLOW-WORM FAULT CODE
Glow-worm F1
An ignition lockout: the boiler tried to light but saw no flame. Usual causes: no gas reaching it, a frozen condensate pipe or a worn electrode.
WHAT F1 TYPICALLY INDICATES
An ignition lockout: the boiler tried to light but saw no flame. Usual causes: no gas reaching it, a frozen condensate pipe or a worn electrode.
WHAT TO DO
Confirm the gas supply is on. Beyond that, This is not a DIY fix — it requires a Gas Safe registered engineer to diagnose and repair safely.
Why a Glow-worm boiler shows F1
Each time there is a call for heat or hot water, the boiler opens its gas valve, sparks the ignition electrode and waits for the flame sensor to confirm a flame. If no flame is confirmed within a few attempts, it shuts the gas off and locks out with F1. The code tells you the ignition sequence failed. It doesn't tell you which part of the sequence failed, which is why the same code can have very different fixes.
The usual causes, roughly in the order they turn up: the gas supply isn't reaching the boiler (an isolation valve knocked off, a prepayment meter out of credit, or a supply problem at the meter); a frozen or blocked condensate pipe in cold weather; a worn, dirty or badly gapped ignition electrode; a flame sensing fault; a gas valve that isn't opening; or, less often, a blocked flue or a fault on the main circuit board.
Checks you can safely make before calling anyone
Check that your gas hob or other gas appliances work. If they don't, the problem is the supply, not the boiler: check the meter, and if you have a prepayment meter make sure it has credit. If you smell gas at any point, stop, open windows, don't use electrical switches and call the National Gas Emergency Service on 0800 111 999.
In freezing weather, look at the plastic condensate pipe where it leaves the house. If it's frozen, pour warm (not boiling) water along it or hold a warm cloth on it until it thaws. A blocked condensate pipe is one of the most common reasons for F1 in winter, and it's the one cause you can clear yourself.
Once you've made those checks, you can reset the boiler once using the reset button described in your user manual. If F1 comes straight back, or returns within a day or two, stop resetting it. Repeated resets won't fix an ignition fault and can make the underlying problem harder to diagnose.
What an engineer does about F1
A Gas Safe registered engineer will check the gas pressure at the boiler, then watch an ignition attempt to see whether there's a spark, whether gas is arriving and whether the flame is being detected. That narrows F1 down to the electrode, the ignition lead, the flame sensing circuit, the gas valve or the board. Cleaning and re-gapping an electrode is a common fix; replacing a gas valve or PCB is more involved, which is why it's worth diagnosing properly before any part is ordered.
If F1 keeps coming back alongside other lockout codes, or the boiler also locks out with F4, F28 or F29, the engineer will treat them as one ignition problem rather than separate faults.
Glow-worm F1: common questions
Can I reset F1 on my Glow-worm boiler?
Yes, once, using the reset button described in the user manual, after you've checked the gas supply and the condensate pipe. If F1 returns, stop resetting and have the ignition system checked by a Gas Safe registered engineer.
Why does my Glow-worm show F1 when it’s freezing outside?
A frozen condensate pipe is the most likely reason. When the pipe freezes, condensate backs up inside the boiler and it stops firing. Thawing the external pipe with warm water, then resetting once, usually clears it.
Is F1 on a Glow-worm dangerous?
F1 is the boiler protecting itself by shutting off the gas after a failed ignition, so the lockout itself is a safety feature. The fault behind it still needs finding. If you smell gas, leave the boiler off and call the gas emergency line on 0800 111 999.
GLOW-WORM GUIDE
Why a Glow-worm boiler keeps locking out
A NOTE ON GAS SAFE REGISTRATION
Any work on the gas side of a boiler in the UK legally requires a Gas Safe registered engineer, it isn't optional. Our engineers are fully Gas Safe registered, and you're always welcome to ask to see ID on the day. This page is general information about what a fault code typically indicates; it is not a substitute for an engineer diagnosing your specific boiler.
MATCHING SERVICE
Boiler Repair in London
Seeing Glow-worm F1 on your boiler?
Tell us the code and your postcode. A fully Gas Safe registered engineer will diagnose the actual cause before quoting a fix.
Book a fault diagnosis